Sign In | Join Free | My frbiz.com
China Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd. logo
Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.
Verified Supplier

1 Years

Home > Gear Pump >

Rexroth A10VSO Hydraulic Piston Pump 100 cm³/rev 350 Bar

Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Rexroth A10VSO Hydraulic Piston Pump 100 cm³/rev 350 Bar

Brand Name : Rexroth

Model Number : A10VSO100DR/31R-PKC62K40 A10VSO100DR/31R-PKC62N00 A10VSO100DR/31R-PKC62N00 A10VSO100DR/31R-PPA12K25 A10VSO100DR/31R-PPA12N00

Certification : ISO

Place of Origin : German

MOQ : 1

Price : 2

Payment Terms : MoneyGram,Western Union,T/T,D/P,D/A,L/C

Supply Ability : 100

Delivery Time : 2 weeks

Packaging Details : wooden box

Transport Package : Wooden Box

Mnr : R902479804

Speed : 3 Speed Settings

Products Name : Rexroth Hydraulic Piston Pump

Model : A10VSO

Rotation : 0.2-cp can be transported in reverse

Type No : AA10VSO71DR/31R-VPA42N00

Seal Type : Nitrile rubber or Viton

Charging : micro5p

Weight : 8.5 kg

Contact Now

A10VSO100DR/31R-PKC62K40 A10VSO100DR/31R-PKC62N00 A10VSO100DR/31R-PKC62N00
A10VSO100DR/31R-PPA12K25 A10VSO100DR/31R-PPA12N00 German variable high-pressure hydraulic pump motor Rexroth plunger pump

Rexroth A10VSO hydraulic pump
1. What are the possible causes and solutions for insufficient or no oil output from the hydraulic pump?
• Reason:
Excessive resistance in the oil suction pipeline (such as clogged oil filter, low oil tank level, or air leakage in the inlet pipe).
Internal leakage of the pump (scratches on the oil distribution plate, poor sealing, sand holes, etc.).
The inclination angle of the inclined plate is too small and the displacement is insufficient.
Motor reversal (requires adjustment of phase sequence).
• Solution:
Clean the oil filter, add oil to the normal liquid level, and check the sealing of the pipeline.
Replace worn parts (such as plungers, oil distribution plates) or grind mating surfaces.
Adjust the variable piston to increase the inclination angle of the inclined plate.
2. How to adjust if there is still traffic output at the median level?
Reason: Deviation, looseness, or wear of the control mechanism (such as wear of the inclined plate ear shaft).
Solution: Reset the controller, tighten or replace damaged parts, and check the angle holding force.
How to troubleshoot the high vibration and noise during pump operation?
• Mechanical reasons:
The pump and motor shaft are not concentric, the coupling is damaged, or the bolts are loose.
Wear of bearings or variable head bearings (dry friction or impurities in the oil during start-up).
• Hydraulic reasons:
The oil inlet pipe is too thin, the oil filter is clogged, or the oil viscosity is too high.
• Solution:
Reinstall and replace worn parts.
Select appropriate oil to ensure smooth fuel tank design and piping.
What are the causes and solutions for overheating of the pump body?
• Reason:
Mechanical friction (such as improper clearance between moving parts) or liquid friction (high-pressure oil leakage converted into thermal energy).
Filter blockage leads to excessive back pressure in the return oil.
• Solution:
Adjust the gap and increase the capacity of the cooler or fuel tank.
Clean or replace the filter.
How to solve the problem of oil leakage?
• Common oil leakage points:
Damaged spindle oil seal, internal leakage (high oil seal pressure), loose external pipeline or aging sealing gasket.
• Solution:
Replace the oil seal or defective shaft, check the size of the oil drain pipe, and tighten the joint.
What are the key points of daily maintenance?
• Oil management:
Maintain oil temperature at 25-60 ℃, cleanliness level ≥ 8, and regularly test oil quality.
• Regular inspection:
Conduct a comprehensive inspection of seals, filters, and mechanical components every 6 months.
After running for 3000 hours, it is necessary to check the status of the oil replenishment pump daily.
Before starting: Ensure that the pump is filled with oil to avoid dry friction.
How to adjust abnormal pressure (too high/too low)?
• Low pressure: Check for pipeline leaks, overflow valve faults, or cylinder block distribution plate leaks.
Excessive pressure: Adjust the overflow valve, check the directional valve or return oil pipeline.
------
precautions
Installation requirements: The concentricity between the pump shaft and the motor shaft should be less than 0.05mm, and the suction height should not exceed 500mm.
• Spare parts replacement: It is recommended to use original seals and wear-resistant components to ensure compatibility.

Rexroth A10VSO Hydraulic Piston Pump 100 cm³/rev 350 Bar

R910907813 A A10VSO100 DFR /31L-PPA12N00

R910917313 A A10VSO100 DFR /31R-PPA12K01

R910998331 A A10VSO100 DFR /31R-PPA12K07

R910942637 A A10VSO100 DFR /31R-PPA12K27

R902417327 A A10VSO100 DFR /31R-PPA12KB4

R902416469 A A10VSO100 DFR /31R-PPA12KB5

R910939643 A A10VSO100 DFR /31R-PPA12N00

R910991002 A A10VSO100 DFR /31R-PSA12N00

R910920969 A A10VSO100 DFR /31R-VPA12N00

R910986270 A A10VSO100 DFR1/31L-PPA12KB4 -SO 32

R910911394 A A10VSO100 DFR1/31R-PPA12K01

R910927083 A A10VSO100 DFR1/31R-PPA12K02

R910983124 A A10VSO100 DFR1/31R-PPA12KB3

R910984741 A A10VSO100 DFR1/31R-PPA12KB4

R910985609 A A10VSO100 DFR1/31R-PPA12KB5

R902403231 A A10VSO100 DFR1/31R-PPA12KB6

R910922744 A A10VSO100 DFR1/31R-PPA12N00

R902418759 A A10VSO100 DFR1/31R-PSA12KB4

R910971805 A A10VSO100 DFR1/31R-PSA12KB6

R910949826 A A10VSO100 DFR1/31R-PSA12N00

R910922681 A A10VSO100 DR /31L-VPA12N00

R910968839 A A10VSO100 DR /31R-PPA12K04

R910916809 A A10VSO100 DR /31R-VPA12N00

R910943447 A A10VSO100 DRG /31R-PPA12N00

R902420121 A A10VSO100 DRG /31R-VPA12K25

R910930899 A A10VSO100 DRG /31R-VPA12N00

R902448357 A A10VSO100 DRG /32R-VPB12N00

R902454561 A A10VSO100 DRS/32R-VPB22U99

R910968510 A A10VSO140 DFLR/31L-PPB12N00

R910972152 A A10VSO140 DFLR/31R-PPB12K02

R910935974 A A10VSO140 DFLR/31R-PPB12N00

R902429793 A A10VSO140 DFLR/31R-VPB12N00

R910921188 A A10VSO140 DFR /31L-PPB12N00

R910933808 A A10VSO140 DFR /31R-PPB12K02

R910939165 A A10VSO140 DFR /31R-PPB12K26

R902410448 A A10VSO140 DFR /31R-PPB12KB4

R910997710 A A10VSO140 DFR /31R-PPB12KB5

R902416467 A A10VSO140 DFR /31R-PPB12KB6

R902416466 A A10VSO140 DFR /31R-PPB12KB7

R910939192 A A10VSO140 DFR /31R-PPB12N00

R910993952 A A10VSO140 DFR /31R-PSB12N00

R910931693 A A10VSO140 DFR /31R-VPB12N00

R910947401 A A10VSO140 DFR1/31R-PPB12K01

R910927126 A A10VSO140 DFR1/31R-PPB12K02

R902433789 A A10VSO140 DFR1/31R-PPB12K07

R910983963 A A10VSO140 DFR1/31R-PPB12KB3

R910983738 A A10VSO140 DFR1/31R-PPB12KB4

R910990335 A A10VSO140 DFR1/31R-PPB12KB5

R910988742 A A10VSO140 DFR1/31R-PPB12KB6

R910921546 A A10VSO140 DFR1/31R-PPB12N00

R910967783 A A10VSO140 DFR1/31R-PPB12N00 -SO516

R902459592 A A10VSO140 DFR1/31R-VPB12

R902465624 A A10VSO140 DFR1/31R-VPB12K07

R902431114 A A10VSO140 DFR1/31R-VPB12KB3

R910927737 A A10VSO140 DR /31L-PPB12N00

R910942862 A A10VSO140 DR /31L-VPB12N00

R910936874 A A10VSO140 DR /31R-PPB12K02

R910960029 A A10VSO140 DR /31R-PPB12K24

R910922983 A A10VSO140 DR /31R-PPB12N00

R910934519 A A10VSO140 DRG /31R-PPB12K01

R910932852 A A10VSO140 DRG /31R-PPB12N00

R902465472 A A10VSO140 DRS /32R-VPB22U99

R910961074 A A10VSO140 FHD /31R-PPB12N00

R910914475 A A2F M 250 /60W-VPB010

R910930970 A A2F M 250 /60W-VPB020

FAQ:

Functional Analysis Document (FAD) – A10VSO100 Series

Document Control

• Prepared By: [Your Name/Team]

• Date: August 18, 2025

• Version: 1.0

• Approved By: [Approver Name]

• Reference No.: [ECN/ECR Number, if applicable]


------

1. Scope

This FAD outlines the functional specifications, performance parameters, and quality requirements for the A10VSO100 series axial piston pumps, including:

• Model Variants: A10VSO100DR/DFR/EP

• Applications: Industrial hydraulics, mobile machinery, and power units.


------

2. Key Specifications

Parameter Value/Range Remarks
Displacement 100 cm³/rev Fixed displacement design
Max Pressure 350 bar (continuous) Peak: 400 bar
Speed Range 800–3600 rpm Dependent on lubrication conditions
Fluid Compatibility Mineral oil (ISO VG 46-68) Temp range: -20°C to +80°C
Efficiency ≥92% (volumetric) Tested per ISO 4409


------

3. Functional Components

• Housing: Aluminum alloy (hardness: HB 90–120).

• Rotating Group: Ceramic-coated pistons for reduced wear.

• Control Mechanism: Pressure compensator (DFR) or load-sensing (EP) options.

• Seals: NBR/FKM materials (valid date: 10 years from manufacture).


------

4. Quality & Testing

• Inspection Criteria:

◦ IQC: Dimensional checks per DWG-100-01 (tolerance ±0.05mm).

◦ IPQC: Leakage test at 1.5x rated pressure (15-min hold).

◦ OQC: Noise level ≤75 dB(A) at 1500 rpm.

• Defect Classification:

◦ Critical (CR): Seal failure, pressure drop >10%.

◦ Major (MA): Surface finish non-conformity.


------

5. Compliance & Standards

• ISO 4409: Hydraulic pump performance testing.

• ISO 13726: Pressure pulsation limits.

• ESD Protection: EPA Class 0 (handling during assembly).


Product Tags:

Rexroth A10VSO hydraulic piston pump

      

100 cm³/rev hydraulic pump

      

350 bar hydraulic piston pump

      
China Rexroth A10VSO Hydraulic Piston Pump 100 cm³/rev 350 Bar wholesale

Rexroth A10VSO Hydraulic Piston Pump 100 cm³/rev 350 Bar Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)